Sign In | Join Free | My burrillandco.com
Home > FM200 Fire Suppression System >

2.5Mpa FM200 fire extinguishing system without residue for archive

    Buy cheap 2.5Mpa FM200 fire extinguishing system without residue for archive from wholesalers
     
    Buy cheap 2.5Mpa FM200 fire extinguishing system without residue for archive from wholesalers
    • Buy cheap 2.5Mpa FM200 fire extinguishing system without residue for archive from wholesalers

    2.5Mpa FM200 fire extinguishing system without residue for archive

    Ask Lasest Price
    Brand Name : Air Giant
    Model Number : GQQ40/2.5, GQQ70/2.5, GQQ90/2.5, GQQ100/2.5, GQQ120/2.5, GQQ150/2.5, GQQ180/2.5
    Certification : CAL,CMA,CNAS,ILAC-MRA,CCC
    Price : negotiation
    Payment Terms : L/C, D/P, T/T, Western Union, Paypal, Credit card
    Supply Ability : 1000 sets per month
    Delivery Time : 10-15 working days
    • Product Details
    • Company Profile

    2.5Mpa FM200 fire extinguishing system without residue for archive

    2.5Mpa FM200 fire extinguishing system without residue for archive

    Fm200(hfc-227ea) is a kind of colorless and tasteless and non-corrosive and electricity-insulating gas without residue and pollution after extinguishing. And ODP of it is zero. It is a friendly-environment gas to be used for extinguishing. Also, because of such feature, it can be used in special place where electrical fire is easy to happen.


    Combined with extinguishing device and electronic accessories, the whole system can be actuated automatically. It can monitor the situation of protective region through detectors and then it can also start the extinguishing device through solenoid actuator automatically. So the whole system can achieve automation totally. Therefore, it can avoid that there is no one who notice the fire when it happens and also it saves much money for employment to supervise the protective area.



    Parameters

    NO.SpecificationsParameters
    1Cylinder capacity40Ltr,70Ltr,90Ltr,100Ltr,
    120Ltr,150Ltr,180Ltr
    2Device modelGQQ40/2.5, GQQ70/2.5, GQQ90/2.5, GQQ100/2.5, GQQ120/2.5, GQQ150/2.5, GQQ180/2.5
    3Filling pressure2.5MPa
    4Max filling rate≤0.95kg/L
    5Discharge time≤10s
    6Working temperature0℃~50℃
    7Max working pressure4.2MPa
    8Discharge pressure5.6±0.28MPa
    9Proportion of protected zone≤500m²
    10Volume of protected zone≤1600m³
    11ActuationAutomatic or manual start



    Cabinet Size

    SpecificationSize(mm)Volume(cbm)Net weight (kg)
    GQQ40/2.5500×450×14500.32633
    GQQ70/2.5500×450×14500.32643-50
    GQQ90/2.5500×450×16500.37143-50(46)
    GQQ100/2.5500×450×16500.37155-64(54)
    GQQ120/2.5550×550×19000.57560-73(60)
    GQQ150/2.5550×550×19000.57580
    GQQ180/2.5600×550×21500.7180



    Compositions:

    The cabinet type fm200 fire suppression system is very easy to install because of a few components. A system is usually divided into two parts, one is the fire extinguishing device part, and the other is the electrical elements part. Because there is a sole part for introducing the electrical part, so the following words are only for talking about the fire extinguishing device part.


    The cabinet type fm200 fire extinguishing device consists of fm200 agent, fm200 cylinder, container valve, flexible hose, liquid flow check valve, nozzle and the cabinet.





    Application

    As its name says, the single zone pipe network fm200 fire suppression system is suitable for a single protected zone, whose volume should be less than 3600 cubic meters as well as proportion should be less than 800 square meters. Because of its property and principles of putting off fire, the single zone pipe network fm200 fire suppression system can be used to protect some large and also significant places, such as the followings:


    - Computer rooms


    - Telecommunication center


    - Facilities underground


    - Offshore oil extraction


    - Library


    - Data and paper archives


    - Valuable article storage


    - Power generator storage room



    Competitive Advantage

    Cabinet fm200 fire suppression system has a large number of advantages, and here is going to have a brief explanation:


    1/ Swift response. Since there is no long distance transportation of pipes, so fm200 gas can be directly discharged into protection zone. Meanwhile, its spraying time is less than 8 second. So it will save more time relatively when the fire happens.


    2/ Convenient installation. Compared with pipe network system, cabinet system would be relatively simple to conduct installation. After installation of control panels and electric components, left work is just to connect it with one cabinet fire extinguishing device or devices. But one room should not be matched with more than 4 pieces of it because of the limitation of the output current of a control panel.


    3/ Lower cost. Obviously, the price would be cheaper than pipe network type for the protection zone which just needs one single cylinder, because there is no need to consider about the expense of pipes and pipe fittings, also the cost of manpower for this part.



    Packages

    We pack products with first polyfoam and then the wooden cases. Once products are too big or customers require a pallet for products, we will make products a pallet. The following pictures are the common packing of products:

    Quality 2.5Mpa FM200 fire extinguishing system without residue for archive for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong Air Giant Fire Equipment Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)