    Brand Name : Air Giant
    Model Number : AG227SP-16.6;AG227SP-28.3;AG227SP-40;AG227SP-49;AG227SP-52;AG227SP-50;AG227SP-60;AG227SP-70;AG227SP-80;AG227SP-90;AG227SP-100;AG227SP-120;AG227SP-150;AG227SP-103;AG227SP-147;AG227SP-153;AG227SP-160;AG227SP-170
    Certification : UL(Urldorwri1er Laboratories Irlc);TPED;GB;DOT
    Price : negotiation
    Payment Terms : L/C, D/P, T/T, Western Union, Paypal, Credit card
    Supply Ability : 28000 sets per week
    Delivery Time : 10-15 working days
    • Product Details
    • Company Profile

    Red Fire Extinguishing System For Anechoic Chamber Non Corrosive HFC227ea

    UL Fire Extinguishing System Without A Residue For Anechoic Chamber Non Corrosive HFC227ea

    Description of UL FM200 Fire Suppression System

    HFC-227ea gas fire extinguishing device usually includes components such as fire extinguishing agent cylinder group (fire extinguishing agent steel cylinder, cylinder head valve), starter (gas starter, electromagnetic starter, manual starter), release hose, one-way valve, low discharge high seal valve, manifold, manifold safety valve, selection valve, drive cylinder group, release pressure switch, nozzle, fire extinguishing agent delivery pipeline, etc. HFC-227ea gas fire extinguishing devices can be divided into single zone systems and multi zone systems based on the number of protected areas, namely unit independent systems and combined distribution systems.


    For a single zone system, after receiving a command from the gas fire extinguishing control panel, the electromagnetic starter opens the bottle head valve (i.e. the active bottle), and the active bottle starts to spray. The gas from the active bottle passes through the starting hose, and opens the bottle head valves (i.e. the driven bottle) of other connected fire extinguishing agent bottle groups, and all gas cylinders start to spray. The extinguishing agent is transported along the pipeline to the protected area and sprayed through nozzles.



    Attributes of UL TPED series cylinders

    Model No.Nominal pressure (bar)Nominal volume(L)Filling volume (kg)

    Caliber

    (mm)

    Weight

    (kg)

    Min.Max.
    AG227SP-25-40D254019.244.84942
    AG227SP-25-50D255024.056.04948
    AG227SP-25-60D256028.867.24953
    AG227SP-25-70D257033.678.44959
    AG227SP-25-80D258038.489.64964
    AG227SP-25-90D259043.2100.84973
    AG227SP-25-100D2510048.0112.04978
    AG227SP-25-120D2512057.6134.44989
    AG227SP-25-150D2515072.0168.049105
    AG227SP-25-160D2516076.8179.249104
    AG227SP-25-16.6C2516.68.018.63321
    AG227SP-25-28.3C2528.313.631.73329
    AG227SP-25-40C254019.244.83337
    AG227SP-25-50C255024.056.03342
    AG227SP-25-60C256028.867.23347
    AG227SP-42-40D424019.244.84942
    AG227SP-42-50D425024.056.04948
    AG227SP-42-60D426028.867.24953
    AG227SP-42-70D427033.678.44959
    AG227SP-42-80D428038.489.64964
    AG227SP-42-90D429043.2100.84973
    AG227SP-42-100D4210048.0112.04978
    AG227SP-42-120D4212057.6134.44989
    AG227SP-42-150D4215072.0168.049105
    AG227SP-42-160D4216076.8179.249104
    AG227SP-42-170D4217081.6190.449108
    AG227SP-42-16.6C4216.68.018.63321
    AG227SP-42-28.3C4228.313.631.73329
    AG227SP-42-40C424019.244.83337
    AG227SP-42-50C425024.056.03342
    AG227SP-42-60C426028.867.23347



    Features of UL FM200 Fire Suppression System

    1. The required concentration is low, which has little visual impact on on-site personnel and reduces personnel risk.

    The 2 system has a relatively low usage, which can minimize overvoltage in the protection zone and maintain the structural safety of the protection zone.

    3. Low toxicity and relatively safe for personnel.

    Short spraying time and fast extinguishing speed are beneficial for reducing fire losses.

    As long as the concentration level is maintained, it can effectively prevent reignition.


    Application of UL FM200 Fire Suppression System

    • In usual commercial or industrial settings, HFC227ea may be applied for fire suppression systems. This system can be used to protect typical areas, such as: Bank strong room Libraries Bookstores Electronic data processing center Telephone switching studio Communication center Transformer and switchgear room Control room Test lab Inflammable liquid storage room


    Packages of UL FM200 Fire Suppression System
    We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.

    Quality Red Fire Extinguishing System For Anechoic Chamber Non Corrosive HFC227ea for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong Air Giant Fire Equipment Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)