    Brand Name : Air Giant
    Model Number : AG5112SPA-16.6;AG5112SPA-20;AG5112SPA-28.3;AG5112SPA-30; AG5112SPA-40;AG5112SPA-49;AG5112SPA-50;AG5112SPA-52; AG5112SPA-60;AG5112SPA-62;AG5112SPA-70;AG5112SPA-80; AG5112SPA-90;AG5112SPA-100;AG5112SPA-103;AG5112SPA-106; AG5112SPA-120;AG5112SPA-140;AG5112SPA
    Certification : UL(Urldorwri1er Laboratories Irlc);TPED;GB;DOT
    Price : negotiation
    Payment Terms : L/C,D/P,T/T,Western Union,Paypal,Credit card
    Supply Ability : 20000 sets per week
    Delivery Time : 10-15 working days
    • Product Details
    • Company Profile

    UL Automatic Fire Suppression System In The Data Center Without Pollution Of NOVEC1230

    UL Automatic Fire Suppression System In The Data Center Without Pollution Of NOVEC1230


    Description of UL NOVEC1230 contianer


    -- Attributes of Seamless Steel TPED series cylinders(40-60L)


    Material

    37Mn

    Carbon:

    0.31-0.38%

    Mn:

    1.40-1.70%

    Si:

    0.17-0.35%

    Cr:

    0.3%

    Ni:

    0.2%

    S:

    0.01%

    P:

    0.02%

    S+P:

    0.025%

    V+Nb+Ti+B+Zr:

    0.15%

    Nominal Working Pressure

    60 bar

    Hydrostatic Test Pressure

    90 bar

    Work Temperature

    -50 °C ~ 65 °C

    Paint Specification

    Red Polyester Powder Coated

    Certification

    TPED


    -- Attributes of Seamless Steel TPED series cylinders(80-180L)


    Material

    30CrMo

    Carbon:

    0.26-0.34%

    Mn:

    0.40-0.70%

    Si:

    0.17-0.37%

    Cr:

    0.8-1.1%

    Mo:

    0.15-0.25%

    S:

    0.01%

    P:

    0.02%

    S+P:

    0.025%

    V+Nb+Ti+B+Zr:

    0.15%

    Nominal Working Pressure

    60 bar

    Hydrostatic Test Pressure

    90 bar

    Work Temperature

    -40 °C ~ 65 °C

    Paint Specification

    Red Polyester Powder Coated

    Certification

    TPED


    -- FK-5-1-12 Seamless Steel Container Assembly Details (TPED Container)


    Cylinder with

    Valve Assembly

    Part No.

    Container

    Assembly

    Type

    Nominal

    Working

    Pressure

    (bar)

    Nominal

    Cylinder

    Volume

    (L)

    Fill Capacity

    (kg)

    Outlet

    Size

    (mm)

    Empty

    Weight

    (kg)

    Min.

    Max.

    813.101.1006

    MS5112SPA-25-20W

    25

    20

    9.6

    22.2

    33

    34

    813.101.1016

    MS5112SPA-25-30W

    30

    14.4

    33.3

    33

    42

    813.101.1026

    MS5112SPA-25-40W

    40

    19.2

    44.4

    33

    51

    813.101.1036

    MS5112SPA-25-50W

    50

    24.0

    55.5

    33

    60

    813.101.0906

    MS5112SPA-25-40U

    40

    19.2

    44.4

    33

    51

    813.101.0916

    MS5112SPA-25-50U

    50

    24.0

    55.5

    33

    60

    813.101.0926

    MS5112SPA-25-60U

    60

    28.8

    66.6

    33

    68

    813.101.0936

    MS5112SPA-25-80U

    80

    60

    88.8

    49

    82

    813.101.0956

    MS5112SPA-25-100U

    100

    60

    111

    49

    93

    813.101.0966

    MS5112SPA-25-120U

    120

    60

    133.2

    49

    104

    813.101.0976

    MS5112SPA-25-140U

    140

    67.2

    155.4

    49

    115

    813.101.0996

    MS5112SPA-25-180U

    180

    86.4

    199.8

    49

    137

    813.101.1008

    MS5112SPA-42-20X

    42

    20

    9.6

    22.2

    33

    34

    813.101.1018

    MS5112SPA-42-30X

    30

    14.4

    33.3

    33

    42

    813.101.1028

    MS5112SPA-42-40X

    40

    19.2

    44.4

    33

    51

    813.101.1038

    MS5112SPA-42-50X

    50

    24.0

    55.5

    33

    60

    813.101.0908

    MS5112SPA-42-40V

    40

    19.2

    44.4

    33

    51

    813.101.0918

    MS5112SPA-42-50V

    50

    24.0

    55.5

    33

    60

    813.101.0928

    MS5112SPA-42-60V

    60

    28.8

    66.6

    33

    68

    813.101.0938

    MS5112SPA-42-80V

    80

    60

    88.8

    49

    82

    813.101.0958

    MS5112SPA-42-100V

    100

    60

    111

    49

    90

    813.101.0968

    MS5112SPA-42-120V

    120

    60

    133.2

    49

    98

    813.101.0978

    MS5112SPA-42-140V

    140

    67.2

    155.4

    49

    106

    813.101.0998

    MS5112SPA-42-180V

    180

    86.4

    199.8

    49

    137


    Description of UL NOVEC1230 Fire Suppression System


    The noise created by the FK-5-1-12 agent discharging can be loud enough to startle people in the vicinity, but is unlikely to cause any permanent injury. Turbulence caused by the high velocity discharge can dislodge substantial objects directly in its path, and cause enough general turbulence within the protected area to move paper and light objects.

    Direct contact with the vaporizing liquid discharged from an FK-5-1-12 nozzle has a chilling effect on objects and in extreme cases can cause frostbite to the skin. The liquid phase vaporises when mixed with air and therefore limits the risk to the immediate vicinity of the nozzle. Minor reduction in visibility may occur for a brief period due to the condensation of water vapour.


    Components of UL NOVEC1230 Fire Suppression System

    UL Automatic Fire Suppression System In The Data Center Without Pollution Of NOVEC1230

    No.

    Part Name

    No.

    Part Name

    1

    Cylinder

    8

    Manifold Check Valve

    2

    Mounting Bracket

    9

    Manifold

    3

    Fix Steel Channel

    10

    Pilot Hose

    4

    Container Valve

    11

    Manifold Safety Valve

    5

    Bleed Valve

    12

    Discharge Pressure Switch

    6

    Pneumatic Actuator

    13

    Electrical Actuator

    7

    Discharge Hose

    14

    Nozzle



    Features of UL NOVEC1230 Fire Suppression System

    1. Environmental protection: Novec1230 / FK-5-1-12 is a non-toxic, colorless, tasteless, non-corrosive, non-conductive and non-explosive fire extinguishing agent, which can protect equipment and environment from damage.

    2. High efficiency: the PFH automatic fire extinguishing system can extinguish the fire quickly in a short time without any damage to the protected equipment.

    3. High safety: Novec1230 / FK-5-1-12 fire extinguishing agent has high stability, is not easy to burn, and will not produce harmful substances. Therefore, the use of this fire extinguishing system can effectively ensure the safety of personnel and equipment.

    4. Strong flexibility: PFH automatic fire extinguishing system can flexibly adapt to different fire extinguishing requirements, and is applicable to various sizes and types of places.


    Application of UL NOVEC1230 Fire Suppression System

    - Computer rooms

    - Telecommunication center

    - Facilities underground

    - Offshore oil extraction

    - Library

    - Data and paper archives

    - Valuable article storage

    - Power generator storage room



    Packages of UL NOVEC1230 Fire Suppression System

    We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.


    UL Automatic Fire Suppression System In The Data Center Without Pollution Of NOVEC1230

    Quality UL Automatic Fire Suppression System In The Data Center Without Pollution Of NOVEC1230 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong Air Giant Fire Equipment Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)