Sign In | Join Free | My burrillandco.com
Home > Novec 1230 Fire Suppression System >

UL Automatic Fire Suppression System In The Data Center Without Pollution Of NOVEC1230

Guangdong Air Giant Fire Equipment Co.,Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap UL Automatic Fire Suppression System In The Data Center Without Pollution Of NOVEC1230 from wholesalers
     
    Buy cheap UL Automatic Fire Suppression System In The Data Center Without Pollution Of NOVEC1230 from wholesalers
    • Buy cheap UL Automatic Fire Suppression System In The Data Center Without Pollution Of NOVEC1230 from wholesalers

    UL Automatic Fire Suppression System In The Data Center Without Pollution Of NOVEC1230

    Ask Lasest Price
    Brand Name : Air Giant
    Model Number : AG5112SPA-16.6;AG5112SPA-20;AG5112SPA-28.3;AG5112SPA-30; AG5112SPA-40;AG5112SPA-49;AG5112SPA-50;AG5112SPA-52; AG5112SPA-60;AG5112SPA-62;AG5112SPA-70;AG5112SPA-80; AG5112SPA-90;AG5112SPA-100;AG5112SPA-103;AG5112SPA-106; AG5112SPA-120;AG5112SPA-140;AG5112SPA
    Certification : UL(Urldorwri1er Laboratories Irlc);TPED;GB;DOT
    Price : negotiation
    Payment Terms : L/C,D/P,T/T,Western Union,Paypal,Credit card
    Supply Ability : 20000 sets per week
    Delivery Time : 10-15 working days
    • Product Details
    • Company Profile

    UL Automatic Fire Suppression System In The Data Center Without Pollution Of NOVEC1230

    UL Automatic Fire Suppression System In The Data Center Without Pollution Of NOVEC1230


    Description of UL NOVEC1230 contianer


    -- Attributes of Welded Steel TPED series container

    Material

    P355M

    Carbon:

    0.14%

    Manganese:

    1.60%

    Silicon:

    0.50%

    Phosphorus:

    0.025%

    Sulphur:

    0.010%

    Nominal Working Pressure

    42 bar ( 609 psi )

    Pneumatic Test Pressure

    63 bar ( 914 psi )

    Burst Test Pressure

    126 bar ( 1827 psi )

    Work Temperature

    -20 °C ~ 65 °C

    Paint Specification

    Red Polyester Powder Coated

    Certification

    TPED


    -- FK-5-1-12 (NOVEC1230) Welded Container Assembly Details :TPED Container

    Cylinder with

    Valve Assembly

    Part No.

    Container

    Assembly

    Type

    Nominal

    Working

    Pressure

    (bar)

    Nominal

    Cylinder

    Volume

    (L)

    Fill Capacity

    (kg)

    Outlet

    Size

    (mm)

    Empty

    Weight

    (kg)

    Min.

    Max.

    813.101.0135

    AG5112SPA-16.6

    25

    16.6

    8.0

    18.4

    33

    21

    813.101.0145

    AG5112SPA-28.3

    28.3

    13.6

    31.4

    33

    29

    813.101.0215

    AG5112SPA-30

    30

    14.4

    33.3

    33

    26.3

    813.101.0155

    AG5112SPA-40

    40

    19.2

    44.4

    33

    37

    813.101.0165

    AG5112SPA-50

    50

    24.0

    55.5

    33

    42

    813.101.0175

    AG5112SPA-60

    60

    28.8

    66.6

    33

    47

    813.101.0185

    AG5112SPA-70

    70

    60

    77.7

    49

    59

    813.101.0195

    AG5112SPA-80

    80

    60

    88.8

    49

    64

    813.101.0196

    AG5112SPA-90

    90

    60

    99.9

    49

    73

    813.101.0216

    AG5112SPA-100

    100

    60

    111

    49

    78

    813.101.0226

    AG5112SPA-120

    120

    60

    133.2

    49

    89

    813.101.0296

    AG5112SPA-142

    142

    68.2

    157.6

    49

    108

    813.101.0236

    AG5112SPA-150

    150

    72.0

    166.5

    49

    105

    813.101.0246

    AG5112SPA-160

    160

    76.8

    177.6

    49

    104

    813.101.0256

    AG5112SPA-170

    170

    81.6

    188.7

    49

    139

    813.101.0266

    AG5112SPA-180

    180

    86.4

    199.8

    49

    144

    813.101.0137

    AG5112SPA-16.6

    42

    16.6

    8.0

    18.4

    33

    21

    813.101.0147

    AG5112SPA-28.3

    28.3

    13.6

    31.4

    33

    29

    813.101.0157

    AG5112SPA-40

    40

    19.2

    44.4

    33

    37

    813.101.0167

    AG5112SPA-50

    50

    24.0

    55.5

    33

    42

    813.101.0177

    AG5112SPA-60

    60

    28.8

    66.6

    33

    47

    813.101.0187

    AG5112SPA-70

    70

    60

    77.7

    49

    59

    813.101.0197

    AG5112SPA-80

    80

    60

    88.8

    49

    64

    813.101.0198

    AG5112SPA-90

    90

    60

    99.9

    49

    73

    813.101.0218

    AG5112SPA-100

    100

    60

    111

    49

    78

    813.101.0228

    AG5112SPA-120

    120

    60

    133.2

    49

    89

    813.101.0298

    AG5112SPA-142

    142

    68.2

    157.6

    49

    108

    813.101.0238

    AG5112SPA-150

    150

    72.0

    166.5

    49

    105

    813.101.0248

    AG5112SPA-160

    160

    76.8

    177.6

    49

    104

    813.101.0258

    AG5112SPA-170

    170

    81.6

    188.7

    49

    108

    813.101.0268

    AG5112SPA-180

    180

    86.4

    199.8

    49

    144





    Description of UL NOVEC1230 Fire Suppression System


    FK-5-1-12 is a clean, safe fire fighting agent for use in total flooding automatic extinguishing systems. It is intended as a long term replacement for Halons, HFCs, and HCFCs, whilst maintaining the excellent fire suppression properties of them, has none of the environmental problems. Storage and distribution requirements are similar to Halon and the majority of system components are identical. However, FK-5-1-12 is not a direct replacement for existing Halon 1301, HFCs and HCFCs installations due to the difference in agent quantity and discharge characteristics. The minimum FK-5-1-12 design concentration for Class A hazard is 4.5%, for Class B hazard is 5.85%, and for Class C hazard is 4.5%.


    Components of UL NOVEC1230 Fire Suppression System

    UL Automatic Fire Suppression System In The Data Center Without Pollution Of NOVEC1230

    No.

    Part Name

    No.

    Part Name

    1

    Cylinder

    8

    Manifold Check Valve

    2

    Mounting Bracket

    9

    Manifold

    3

    Fix Steel Channel

    10

    Pilot Hose

    4

    Container Valve

    11

    Manifold Safety Valve

    5

    Bleed Valve

    12

    Discharge Pressure Switch

    6

    Pneumatic Actuator

    13

    Electrical Actuator

    7

    Discharge Hose

    14

    Nozzle



    Features of UL NOVEC1230 Fire Suppression System

    1.The low concentration of FK-5-1-12 required means less visual obscurity and minimal risk to personnel.

    2.Maximum safety for personnel due to low toxicity.

    3.Most effective when used with automatic detection to introduce FK-5-1-12 rapidly.

    4.The ability to prevent re-ignition as long as concentration levels are maintained.

    5.Colorless, with low odor with no particulate or oily residue allowing for minimal business disruption after a discharge.

    6.Space saving, quantity of FK-5-1-12 fluid needed to suppress fires typically required minimal cylinders, thus minimal space required.



    Application of UL NOVEC1230 Fire Suppression System

    - Telecommunications and data processing

    - Switch gear rooms

    - Military applications and cell sites

    - High-tech medical application

    - Computer rooms

    - Telecommunication centers

    - Records and data archives

    - Testing/imaging equipment

    - Reference material

    - Chemical laboratories



    Packages of UL NOVEC1230 Fire Suppression System

    We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.


    UL Automatic Fire Suppression System In The Data Center Without Pollution Of NOVEC1230

    Quality UL Automatic Fire Suppression System In The Data Center Without Pollution Of NOVEC1230 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong Air Giant Fire Equipment Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)